SOLAR Management System

SOLAR Management System

See in real time how much your solar produces, and how much it cuts your bill and CO2

Solar reduces the power you buy from the grid, but once it is installed many plants can't tell whether every array is still producing fully or what share of their power comes from solar, and an inverter or panel fault can go unnoticed for days.

The Challenge

Is it producing fully?

Dirty or degraded panels and faulty inverters quietly reduce output.

No view of the energy mix

The share of solar versus grid power is unknown.

Legal limits

Over-generation or abnormal frequency must be handled immediately.

Data in many places

Inverter, PCS and battery data sit in separate systems.

Proving the return

Management wants energy-saving and CO2-reduction figures.

Our Approach

Generation and consumption overview

Solar generation against the upstream supply, self-sufficiency, energy saved and CO2 avoided, in graphics designed to the customer's needs.

Overview screen: energy produced, consumption share and CO2 reduction
Overview screen: energy produced, consumption share and CO2 reduction

Every array and inverter

Output of each array and inverter on the real site layout, to spot under-performing sections.

Site layout screen: output of each array and inverter
Site layout screen: output of each array and inverter

PCS and battery detail

Power (kW), energy (kWh), frequency (Hz), temperature, humidity and battery capacity, with trends.

PCS screen: electrical values, temperature and trends
PCS screen: electrical values, temperature and trends

Alarms and protection

Alarms for low output or abnormal frequency, and shutdown when generation exceeds the legal limit.

Operation screen: PCS status and alarms
Operation screen: PCS status and alarms

Key Features

Generation Overview

  • Generation against the upstream supply
  • Solar self-sufficiency (%)
  • Energy saved and CO2 avoided

Inverter & PCS

  • Power (kW), energy (kWh), frequency (Hz)
  • Temperature, humidity and battery capacity

Protection & Alarm

  • Alarm on below-normal output
  • Shutdown above the legal limit
  • Alarm on abnormal frequency

History & Report

  • Data logging and history
  • Graphs and reports in the customer's format

System Architecture

Field Level

Inverters, PCS, batteries, power meters and weather sensors over Modbus RTU / TCP.

Control Level

PLC or gateway collects data and trips generation above the set limits.

Display & Report

SCADA and dashboards with alarms, graphs and reports.

The Result

Full production

Under-performing arrays or inverters are seen at once, not days later.

Proven return

Energy-saving and CO2 figures ready for management.

Safe and compliant

Generation kept within limits and protected against abnormal frequency.

One place for all data

Inverters, PCS and batteries on one screen.