Boiler Management System
Boiler Management System
Know your boiler's efficiency every hour, from the fuel going in to the steam reaching production
The boiler is the heart of any plant that runs on steam, and it burns a lot of fuel every day. Yet many plants still write readings down by hand, so nobody knows how much fuel each tonne of steam really takes, and an abnormal water level or pressure may be noticed too late.
The Challenge
Manual, patchy readings
Temperatures, pressures and steam output are logged now and then, leaving gaps when you need to look back.
Unknown real efficiency
Nobody can tell whether the fuel burned matches the steam produced, or when efficiency starts to drop.
Safety risks
Low water level or excessive steam pressure must be seen and handled immediately.
Feed water quality
pH and conductivity affect boiler life, but are usually only checked occasionally.
Many separate subsystems
Fuel feed, feed pumps, deaerator and dust collection are watched separately, so the big picture is hard to see.
Our Approach
Survey the whole steam cycle
From feed water and deaerator through the boiler, fuel feed and dust collection to the steam supplied to production, so every point in the cycle is measured.

Install instruments
Temperature, pressure and level sensors, flow meters for steam, feed water and fuel, water-quality analysers (pH, conductivity) and power meters on the motors.

Display and calculate efficiency
SCADA shows every point in real time and automatically calculates boiler efficiency (LHV / HHV), steam and feed water totals and fuel consumption.

Control and alarms
PID control valves, dampers and blowdown valves, with instant alarms for high steam pressure or low water level.

Key Features
Real-time Monitoring
- Status of each boiler
- Inlet / outlet water temperature and steam temperature to production
- System pressure and flow
Efficiency & Fuel
- Boiler efficiency (LHV / HHV)
- Steam, feed water and fuel totals
- Fuel and energy per unit of steam
Water Quality
- pH, conductivity and phosphate
- Automatic blowdown valve control
Combustion Control
- PID control valves
- Damper and fan speed adjustment
Alarm, History & Report
- Alarms for high pressure, low water level and other faults
- History, graphs and reports
System Architecture
Field Level
Temperature, pressure and level sensors, flow meters, water-quality analysers, drives and power meters.
Control Level
PLC runs the control valves, dampers, blowdown and boiler sequencing.
Display & Report
Control-room SCADA with alarms, graphs and reports, ready to extend to an IoT & Cloud Dashboard.
The Result
Efficiency every hour
See immediately when efficiency drops, and find the cause in real data.
Safer operation
Instant alarms for abnormal pressure and water level, without waiting for rounds.
Longer boiler life
Continuous water-quality monitoring and well-controlled blowdown.
Fuel costs under control
Fuel use against steam output for planning and reporting.
How efficiently is your boiler using fuel?
MEC AUTOMATION CO. · Contact us for a site survey
Services: Air Compressor Management System, Chiller Plant Management System, Boiler Management System, Water Plant Management System, Energy Monitoring, IoT and Cloud Dashboard



