Chiller Management System
Chiller Management System
Chillers, pumps, valves and cooling towers working together, from one screen
A chilled-water system has many parts working together: chillers, chilled water pumps (CHP), condenser water pumps (CDP), valves and cooling towers. Without central control, the water temperature sent to production drifts and energy is wasted.
The Challenge
Unstable water temperature
Chilled water to production swings up and down, affecting product quality and the process.
Running by habit
Chillers and pumps follow an old routine instead of the actual load.
Checking unit by unit
Chiller, pump and cooling tower status is spread over many places, with no overview.
Late problem detection
Chiller faults or high water temperature are noticed only after production is affected.
No history
No reports for analysis or maintenance planning.
Our Approach
Everything on one diagram
Chillers, CHP / CDP pumps, valves and cooling towers connected to SCADA, with water temperature, pressure and flow for the whole system on one diagram.

Control and schedules
Select operating modes, set temperatures for each zone and schedule the system from the control room.

Detail for every unit
Evaporator and condenser water temperatures, compressor status, electrical values and maintenance data for each chiller.

Key Features
Real-time Monitoring
- Status of chillers, CHP / CDP pumps, valves and cooling towers
- Water temperature before production
Temperature & Flow
- Evaporator and condenser inlet / outlet water temperatures
- System water pressure and flow
Control & Schedule
- Operating modes and zone temperature setpoints
- System operating schedules
Alarm, History & Report
- Alarms for chiller faults or abnormal water temperature
- Historical reports on demand
System Architecture
Field Level
Temperature and pressure sensors, flow meters and power meters, with chillers connected over Modbus or BACnet.
Control Level
PLC sequences chillers, pumps, valves and cooling towers.
Display & Report
Control-room SCADA with alarms, graphs and reports.
The Result
Steadier chilled water
Consistent water temperature to production.
The whole system on one screen
Every unit's status at all times, without walking the plant.
Problems caught early
Instant alarms for chiller faults or abnormal water temperature.
Ready for CPMS
Plant-wide kW/TR efficiency analysis with the Chiller Plant Management System (CPMS).
Want a steadier, more efficient chilled-water system?
MEC AUTOMATION CO. · Contact us for a site survey
Services: Air Compressor Management System, Chiller Plant Management System, Boiler Management System, Water Plant Management System, Energy Monitoring, IoT and Cloud Dashboard